GUIDE TO INSTALLATION AND OPERATION
UAP-1783 | 25
3.3.9 Reference Input
Reference – Desired:
Use a radio button to select a reference signal for
the UAP-1783. The reference sources are placed
by order of priority where ABUS has the highest
priority. The absence of the selected reference is
an error condition.
Select Auto in the header bar to
automatically select the highest-priority
reference present and valid.
Reference – Current:
This section indicates the current reference used
by the UAP-1783. Many reference sources may be
present and valid. When a valid reference is not
present, the UAP-1783 reverts to Free-Run mode
(this is an error condition).
Reference – Presence:
Five dedicated presence indicators display the
valid reference sources: one for a reference card
REF-17xx in slot 10 of the Densité frame, one for
a reference card REF-1xxx in slot 20, and one for
a valid AES1 input signal.
The URS is a single signal that is capable of
distributing to all cards in a Densité frame a
frequency reference and frame alignment
references for all video and audio signals.