Miranda UAP-1783 Operations Instructions Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 35
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
GUIDE TO INSTALLATION AND OPERATION
6 | UAP-1783
3.2.1 Status LED
The status monitor LED is located on the front card-edge of the UAP-1783, and is visible through the front
access door of the DENSITÉ frame. This multi-color LED indicates module status by color, and by
flashing/steady illumination, according to the chart. The chart also indicates fault reporting for this card on the
DENSITÉ frame’s serial and GPI interfaces.
Serial
Report
GPI
Report Green Yellow Red
Flashing
Red
Flashing
Yellow
Card system error
-
Not expected reference Error
-
Reference error
AES carrier no lock
-
AES carrier biphase
-
AES carrier parity
-
AES carrier CRCC
-
AES carrier invalid sample
-
AES PCM presence
AES Non-PCM presence
AES Dolby E presence
AES AC-3 presence
NSD CH 1 to 4 Analog input
-
NSD CH 5 to 8 Digital input
-
NSD CH 9 to 16 (Ext.CH 1/8 or 9/16)
-
OVERLOAD CH 1 to 4 analog inputs
OVERLOAD CH 1 to 16 processing
-
OVERLOAD analog outputs 1 to 4
OVERLOAD digital outputs 5 to 8
Any TONE activated
-
Any output Mute
-
User attention - - - - - - Yes
Rear panel error - - - - - Yes -
FPGA error - - - - - Yes
: Factory default.
Note: The non-requested message posting to an alarm status can only be accessed by the
communication protocol (serial port)
NOTE: A “Flashing Yellow” Status LED indicates that the SELECT button on the front panel has been
pushed.
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 34 35