52
Peripheral Equipment
Audio Inputs
2
of input connections available, this link transports up to 128 channels of audio. The SDTI streams transport
the current IP address of the Audio Bridge Terminal to the receiver. The connection via TCP/IP will give
access to the different parameters and status.
Audio Inputs
Analog Audio Inputs
The analog channels pass through analog to digital converters with 24 bit resolution and a 48 kHz sample
rate. To compensate the level of the analog signal, the 0 dBFS value may be set from +24 dBu to -7 dBu for
each channel through the Web page interface.
Digital Audio Inputs
The ABT operates on at 48 kHz-sampled audio signals, and inputs at different sampling rates may not be
processed satisfactorily. The validity, user and channel status bits are transmitted alongside the PCM
samples. The input error status detected by the digital input receiver can be monitored by the Web page
interface. The non-PCM data will pass unchanged.
Web Interface
To access the Web interface, the ABT must be connected to a local area network (LAN). If the unit's IP
address is known, you can access the built-in Web server by entering the address in a Web browser
connected to the same network.
If the IP address is not known, it is possible to reset the unit's network configuration. You must set up a
simple LAN comprised of:
one PC running the Web browser
the ABT to be configured
a hub or switch for interconnection.
To connect the ABT to the LAN, do the following:
1. Connect the PC to the hub or switch.
2. Set the PC network configuration with the following parameters:
Page view 57