7
Monitoring the Temperature of the Kaleido-X16 Frame
For optimal performance, it is strongly recommended that you operate the Kaleido-X16 frame in an
environment with an ambient temperature between 0ºC and 40ºC.
There are two factors that could influence airflow inside the frame: altitude and airflow obstruction on the
sides of the unit.
LED LED Status
Green Blinking
green
Red Blinking red Yellow Blinking
yellow
Off
CPU
Normal
operation
Application
booting
Error Live Update OS Booting N/A N/A
CPF
Activity
N/A Activity N/A N/A N/A N/A No
Activity
Video
Inputs
Inputs are locked N/A Inputs
unlocked, or
•no input
ERROR ON
SIGNAL
N/A N/A N/A
DVI Inputs
Inputs are locked N/A Inputs are
unlocked, or
•no input
ERROR ON
SIGNAL
N/A N/A N/A
LTC
LTC valid N/A LTC invalid N/A N/A N/A No signal
Ex. Ref.
Input
Input is locked N/A Input is
unlocked, or
•no input
ERROR ON
SIGNAL
N/A N/A N/A
SDTI
Inputs are locked N/A Inputs are
unlocked, or
no input, or
•no SDTI signal
ERROR ON
SIGNAL
N/A N/A N/A
General
Status
System OK Intrusive self-
diagnostic
finished
Config Failed/
Safe Mode
FW Upgrading Boot up
Diagnostic
(Verbose switch
on)
Firmware error N/A
Severity
Boot OK Booting Boot error
Need live-
update
Fatal error
CALL TECH
SUPPORT
N/A N/A No power
IMPORTANT: When measuring the ambient room temperature, take your readings from directly in front of the
Kaleido-X16 frame.