GUIDE TO INSTALLATION AND OPERATION
4 | SPG-1801
3 Operation
3.1 Control Options
The SPG-1801 has two primary control interfaces:
The local control panel attached to the Densité frame’s controller
Remote control using Miranda’s iControl system
These will be explained in detail in the following sections.
3.2 Local control using the Densité frame control panel
Push the SELECT button on the SPG-1801 card edge (see Section 1.4) to assign the local control panel to operate
the SPG-1801. Use the control panel buttons to navigate through the menu, as described below.
All of the cards installed in a Densité frame are connected to the frame’s controller card, which handles all interaction
between the cards and the outside world. There are no operating controls located on the cards themselves. The
controller supports remote operation via its Ethernet ports, and local operation using its integrated control panel.
The local control panel is fastened to the controller
card, and when installed is located in the front center of
the frame, positioned in front of the power supplies. The
panel consists of a display unit capable of displaying
two lines of text, each 16 characters in length, and five
pushbuttons.
The panel is assigned to operate any card in the frame
by pushing the SELECT button on the front edge of that
card. Pushing the CONTROLLER button on the control
panel selects the Controller card itself. The STATUS
LED on the selected card flashes yellow.
The local control panel displays a menu that can be navigated using the four pushbuttons located beside the display.
The functionality of the pushbuttons on the panel is as follows:
[CTRL] Selects the controller card for status monitoring and adjustment
[+] [–] Used for menu navigation and value modification
[SELECT] Gives access to the next menu level. When a parameter value is shown, pushing this button once
enables modification of the value using the [+] and [] buttons; a second push confirms the new value
[ESC] Cancels the effect of parameter value changes that have not been confirmed; pushing [ESC] causes the
parameter to revert to its former value.
Pushing [ESC] moves the user back up to the previous menu level. At the main menu, [ESC] does not
exit the menu system. To exit, re-push the [SELECT] button for the card being controlled.
If no controls are operated for 30 seconds, the controller reverts to its normal standby status, and the selected card’s